Senseca PRO thermometer
Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)
Install
Add this to your client's MCP configuration (Claude Desktop: claude_desktop_config.json; Cursor: .cursor/mcp.json; VS Code and others use the same "mcpServers" shape).
mcp-server-senseca-proclaude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1
{
"mcpServers": {
"senseca-pro-thermometer": {
"command": "uvx",
"args": [
"mcp-server-senseca-pro==0.1.1"
],
"env": {
"SENSECA_PORT": "<SENSECA_PORT>",
"SENSECA_PIN": "<your senseca_pin>",
"SENSECA_ALLOW_WRITE": "0"
}
}
}
}
Environment variables
SENSECA_PORTSerial port of the instrument, e.g. /dev/ttyACM0 or COM3. Auto-detected if not set.SENSECA_PINsecret Instrument PIN, only needed if its protected mode is enabledSENSECA_ALLOW_WRITESet to 1 to enable tools that change instrument settings (clock, location labels)
Documentation
From the project's README on GitHub, refreshed weekly. Links open on GitHub.
mcp-server-senseca-pro
An MCP server that lets AI assistants read live measurements from a Senseca PRO 111 / PRO 115 handheld Pt100 thermometer connected via USB.
Unofficial project, not affiliated with or endorsed by Senseca. Tested with a PRO 111, firmware V1.4.3.0, interface protocol V1.0.0.1.
Tools
| Tool | Description |
|---|---|
read_temperature | Current temperature with unit (°C/°F/K, as set on the instrument) and UTC timestamp |
read_resistance | Current Pt100 resistance in ohm |
sample_temperature | Readings over a period (max 600 s, interval ≥ 0.5 s) with min/max/mean/stdev |
get_device_info | Model, serial number, firmware, instrument clock, battery level |
With --allow-write two more tools are available:
| Tool | Description |
|---|---|
set_device_clock | Set the instrument clock (default: this computer's time) |
set_location_name | Rename one of the 20 location labels |
The server cannot change calibration or adjustment data; the instrument does not offer that over its serial interface.
Requirements
- Python ≥ 3.10 and uv
- The instrument switched on and connected via USB-C. On the PRO 115 set Settings → USB mode to COM interface.
- Linux: your user must be in the
dialoutgroup (sudo usermod -aG dialout $USER, then log in again). - Windows / macOS: no extra setup; the port shows up as
COMxor/dev/cu.usbmodem….
Configuration
Claude Code
claude mcp add senseca-pro -- uvx mcp-server-senseca-pro
Claude Desktop and other clients
{
"mcpServers": {
"senseca-pro": {
"command": "uvx",
"args": ["mcp-server-senseca-pro"]
}
}
}
Options
| Option | Environment variable | Default |
|---|---|---|
--port PORT | SENSECA_PORT | auto-detect |
--allow-write | SENSECA_ALLOW_WRITE=1 | off |
--log-level LEVEL | SENSECA_LOG_LEVEL | WARNING |
| — | SENSECA_PIN | none; needed only if the instrument's protected mode is on |
Auto-detection looks for USB ID 0483:5740 and only accepts a port whose device reports
manufacturer senseca. If several instruments are connected, set the port explicitly; on Linux
prefer the stable /dev/serial/by-id/… path.
Only one program can use the serial port at a time. Close ProXware or terminal programs while the server is running.
Measurement notes
- Instrument accuracy: ±0.05 °C or ±0.06 % of reading (whichever is higher) ±1 digit, probe not included.
- The USB port is not galvanically isolated. With a probe touching a grounded medium, the USB connection can shift the reading. Compare readings with and without USB, and use a USB isolator if they differ (see the instrument manual, section 7.2).
Development
uv sync
uv run pytest # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-senseca-pro # try the tools interactively
The serial protocol is described in docs/protocol.md.
License
MIT
Frequently asked questions
What is Senseca PRO thermometer?
Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)
How do I install Senseca PRO thermometer?
It runs on your machine. In Claude Code: claude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1. For other clients, paste the JSON configuration from this page into their MCP settings.
Does Senseca PRO thermometer need an API key?
Yes. It expects SENSECA_PIN, which you set in its configuration.
Is Senseca PRO thermometer open source?
Yes. Its code is on GitHub under the MIT license.
Who maintains Senseca PRO thermometer?
It is published by shaag7967. AI.tn lists it but does not maintain or endorse it.
From the official MCP Registry. Listing is not an endorsement: review a server's code and permissions before giving it access to your data.