Senseca PRO thermometer

Official registry Other

Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)

Install

Add this to your client's MCP configuration (Claude Desktop: claude_desktop_config.json; Cursor: .cursor/mcp.json; VS Code and others use the same "mcpServers" shape).

PYPI package mcp-server-senseca-pro
Claude Code
claude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1
JSON configuration (Claude Desktop, Cursor, VS Code)
{
    "mcpServers": {
        "senseca-pro-thermometer": {
            "command": "uvx",
            "args": [
                "mcp-server-senseca-pro==0.1.1"
            ],
            "env": {
                "SENSECA_PORT": "<SENSECA_PORT>",
                "SENSECA_PIN": "<your senseca_pin>",
                "SENSECA_ALLOW_WRITE": "0"
            }
        }
    }
}

Environment variables

  • SENSECA_PORT Serial port of the instrument, e.g. /dev/ttyACM0 or COM3. Auto-detected if not set.
  • SENSECA_PIN secret Instrument PIN, only needed if its protected mode is enabled
  • SENSECA_ALLOW_WRITE Set to 1 to enable tools that change instrument settings (clock, location labels)

Documentation

From the project's README on GitHub, refreshed weekly. Links open on GitHub.

Contents
  1. mcp-server-senseca-pro
  2. Tools
  3. Requirements
  4. Configuration
  5. Measurement notes
  6. Development
  7. License

mcp-server-senseca-pro

An MCP server that lets AI assistants read live measurements from a Senseca PRO 111 / PRO 115 handheld Pt100 thermometer connected via USB.

Unofficial project, not affiliated with or endorsed by Senseca. Tested with a PRO 111, firmware V1.4.3.0, interface protocol V1.0.0.1.

Tools

ToolDescription
read_temperatureCurrent temperature with unit (°C/°F/K, as set on the instrument) and UTC timestamp
read_resistanceCurrent Pt100 resistance in ohm
sample_temperatureReadings over a period (max 600 s, interval ≥ 0.5 s) with min/max/mean/stdev
get_device_infoModel, serial number, firmware, instrument clock, battery level

With --allow-write two more tools are available:

ToolDescription
set_device_clockSet the instrument clock (default: this computer's time)
set_location_nameRename one of the 20 location labels

The server cannot change calibration or adjustment data; the instrument does not offer that over its serial interface.

Requirements

  • Python ≥ 3.10 and uv
  • The instrument switched on and connected via USB-C. On the PRO 115 set Settings → USB mode to COM interface.
  • Linux: your user must be in the dialout group (sudo usermod -aG dialout $USER, then log in again).
  • Windows / macOS: no extra setup; the port shows up as COMx or /dev/cu.usbmodem….

Configuration

Claude Code
claude mcp add senseca-pro -- uvx mcp-server-senseca-pro
Claude Desktop and other clients
{
  "mcpServers": {
    "senseca-pro": {
      "command": "uvx",
      "args": ["mcp-server-senseca-pro"]
    }
  }
}
Options
OptionEnvironment variableDefault
--port PORTSENSECA_PORTauto-detect
--allow-writeSENSECA_ALLOW_WRITE=1off
--log-level LEVELSENSECA_LOG_LEVELWARNING
—SENSECA_PINnone; needed only if the instrument's protected mode is on

Auto-detection looks for USB ID 0483:5740 and only accepts a port whose device reports manufacturer senseca. If several instruments are connected, set the port explicitly; on Linux prefer the stable /dev/serial/by-id/… path.

Only one program can use the serial port at a time. Close ProXware or terminal programs while the server is running.

Measurement notes

  • Instrument accuracy: ±0.05 °C or ±0.06 % of reading (whichever is higher) ±1 digit, probe not included.
  • The USB port is not galvanically isolated. With a probe touching a grounded medium, the USB connection can shift the reading. Compare readings with and without USB, and use a USB isolator if they differ (see the instrument manual, section 7.2).

Development

uv sync
uv run pytest                                   # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-senseca-pro   # try the tools interactively

The serial protocol is described in docs/protocol.md.

License

MIT

Frequently asked questions

What is Senseca PRO thermometer?

Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)

How do I install Senseca PRO thermometer?

It runs on your machine. In Claude Code: claude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1. For other clients, paste the JSON configuration from this page into their MCP settings.

Does Senseca PRO thermometer need an API key?

Yes. It expects SENSECA_PIN, which you set in its configuration.

Is Senseca PRO thermometer open source?

Yes. Its code is on GitHub under the MIT license.

Who maintains Senseca PRO thermometer?

It is published by shaag7967. AI.tn lists it but does not maintain or endorse it.