Senseca PRO thermometer
Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)
التثبيت
أضف هذا إلى إعدادات MCP في عميلك (Claude Desktop: claude_desktop_config.json، وCursor: .cursor/mcp.json، ويستخدم VS Code وغيره الصيغة نفسها «mcpServers»).
mcp-server-senseca-proclaude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1
{
"mcpServers": {
"senseca-pro-thermometer": {
"command": "uvx",
"args": [
"mcp-server-senseca-pro==0.1.1"
],
"env": {
"SENSECA_PORT": "<SENSECA_PORT>",
"SENSECA_PIN": "<your senseca_pin>",
"SENSECA_ALLOW_WRITE": "0"
}
}
}
}
متغيرات البيئة
SENSECA_PORTSerial port of the instrument, e.g. /dev/ttyACM0 or COM3. Auto-detected if not set.SENSECA_PINسري Instrument PIN, only needed if its protected mode is enabledSENSECA_ALLOW_WRITESet to 1 to enable tools that change instrument settings (clock, location labels)
التوثيق
مأخوذ من ملف README للمشروع على GitHub ويُحدَّث أسبوعيًا. تفتح الروابط على GitHub.
mcp-server-senseca-pro
An MCP server that lets AI assistants read live measurements from a Senseca PRO 111 / PRO 115 handheld Pt100 thermometer connected via USB.
Unofficial project, not affiliated with or endorsed by Senseca. Tested with a PRO 111, firmware V1.4.3.0, interface protocol V1.0.0.1.
Tools
| Tool | Description |
|---|---|
read_temperature | Current temperature with unit (°C/°F/K, as set on the instrument) and UTC timestamp |
read_resistance | Current Pt100 resistance in ohm |
sample_temperature | Readings over a period (max 600 s, interval ≥ 0.5 s) with min/max/mean/stdev |
get_device_info | Model, serial number, firmware, instrument clock, battery level |
With --allow-write two more tools are available:
| Tool | Description |
|---|---|
set_device_clock | Set the instrument clock (default: this computer's time) |
set_location_name | Rename one of the 20 location labels |
The server cannot change calibration or adjustment data; the instrument does not offer that over its serial interface.
Requirements
- Python ≥ 3.10 and uv
- The instrument switched on and connected via USB-C. On the PRO 115 set Settings → USB mode to COM interface.
- Linux: your user must be in the
dialoutgroup (sudo usermod -aG dialout $USER, then log in again). - Windows / macOS: no extra setup; the port shows up as
COMxor/dev/cu.usbmodem….
Configuration
Claude Code
claude mcp add senseca-pro -- uvx mcp-server-senseca-pro
Claude Desktop and other clients
{
"mcpServers": {
"senseca-pro": {
"command": "uvx",
"args": ["mcp-server-senseca-pro"]
}
}
}
Options
| Option | Environment variable | Default |
|---|---|---|
--port PORT | SENSECA_PORT | auto-detect |
--allow-write | SENSECA_ALLOW_WRITE=1 | off |
--log-level LEVEL | SENSECA_LOG_LEVEL | WARNING |
| — | SENSECA_PIN | none; needed only if the instrument's protected mode is on |
Auto-detection looks for USB ID 0483:5740 and only accepts a port whose device reports
manufacturer senseca. If several instruments are connected, set the port explicitly; on Linux
prefer the stable /dev/serial/by-id/… path.
Only one program can use the serial port at a time. Close ProXware or terminal programs while the server is running.
Measurement notes
- Instrument accuracy: ±0.05 °C or ±0.06 % of reading (whichever is higher) ±1 digit, probe not included.
- The USB port is not galvanically isolated. With a probe touching a grounded medium, the USB connection can shift the reading. Compare readings with and without USB, and use a USB isolator if they differ (see the instrument manual, section 7.2).
Development
uv sync
uv run pytest # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-senseca-pro # try the tools interactively
The serial protocol is described in docs/protocol.md.
License
MIT
الأسئلة الشائعة
ما هو Senseca PRO thermometer؟
Live readings from Senseca PRO 111/115 Pt100 thermometers via USB (unofficial)
كيف أثبّت Senseca PRO thermometer؟
يعمل على جهازك. في Claude Code: claude mcp add senseca-pro-thermometer -e 'SENSECA_PORT=<SENSECA_PORT>' -e 'SENSECA_PIN=<your senseca_pin>' -e 'SENSECA_ALLOW_WRITE=0' -- uvx mcp-server-senseca-pro==0.1.1. وفي العملاء الآخرين، الصق إعداد JSON من هذه الصفحة في إعدادات MCP الخاصة بهم.
هل يحتاج Senseca PRO thermometer إلى مفتاح API؟
نعم. يتطلب SENSECA_PIN، وتضبطها في إعداداته.
هل Senseca PRO thermometer مفتوح المصدر؟
نعم. شيفرته متاحة على GitHub بترخيص MIT.
من يصون Senseca PRO thermometer؟
ينشره shaag7967. يدرجه AI.tn لكنه لا يصونه ولا يوصي به.
من سجل MCP الرسمي. الإدراج ليس توصية: راجع شيفرة الخادم وصلاحياته قبل منحه الوصول إلى بياناتك.