RackArchitect MCP
3D/2D Rack-as-Code homelab planner, 5-stage validator, CAD SVG/BOM & watertight STL generator.
Installation
Ajoutez ceci à la configuration MCP de votre client (Claude Desktop : claude_desktop_config.json ; Cursor : .cursor/mcp.json ; VS Code et les autres utilisent la même forme « mcpServers »).
https://github.com/itAlex240/rack-architect-mcp/releases/download/v0.2.0/rack-architect-mcp.mcpbDocumentation
Tirée du README du projet sur GitHub, actualisée chaque semaine. Les liens ouvrent GitHub.
Sommaire
- 🏗️ RackArchitect MCP (@rack-mcp/*)
- 🎯 Why RackArchitect MCP? (The Three Golden Laws)
- 🖼️ Generated CAD Blueprints (100% Deterministic SVG Output)
- 🚀 30-Second Quickstart
- 🤖 Connect Claude Desktop, Cursor, or Antigravity
- 🖨️ Parametric 3D-Print Generator (.scad & .stl)
- 🖥️ Live 3D Digital Twin & 2D CAD Web-Viewer (127.0.0.1:3100)
- 🛡️ 5-Stage Validation Engine (All 26 Diagnostic Codes)
- 📦 Monorepo Architecture (packages/*)
- 🤝 Contributing & Adding Hardware Blueprints
- 📄 License
🏗️ RackArchitect MCP (@rack-mcp/*)
The Open-Source, Agent-First "Rack-as-Code" Planning, 5-Stage Validation, Parametric 3D-Print (.scad/.stl) & Live 2D/3D CAD Platform for 19-Inch Enterprise Racks, 10-Inch Mini-Racks & 6-Inch Micro-Homelabs
**🌐 Launch Live 3D/2D Browser Demo** · **Quickstart** · **MCP Client & Agent Skill** · **3D-Print (.SCAD / .STL)** · **Add Hardware Blueprint** · **Complete Handbook (DE)**
🎯 Why RackArchitect MCP? (The Three Golden Laws)
Planning a compact 10-inch mini-rack (e.g., DeskPi RackMate T1/T2, Digitus SOHO) or a dense 19-inch homelab with AI agents used to fail for one reason: LLMs hallucinate physical geometry. They forget that a 55 mm Schuko plug on a rear PDU collides with a 182 mm Lenovo ThinkCentre M920q mounted in front, or that two fanless PoE switches stacked together create a thermal hotspot.
RackArchitect MCP solves this with three non-negotiable engineering laws:
- LLMs Never Guess Geometry: Every spatial coordinate (
1 U = 44.45 mm), 3D Axis-Aligned Bounding Box (B_chassis+ dynamic plug clearance $\Delta Z_{\text{plug}}$), Catmull-Rom 3D cable spline, PoE budget DAG, and logarithmicdB(A)acoustic sum is computed deterministically in millimeters by@rack-mcp/core-domain. - Single Source of Truth (
rack.yaml): Your entire rack state (devices, 3D-printed sub-U carrier slots, child mini-PCs, keystone couplers, cables, VLANs, and IP CIDRs) lives in a single, Git-friendly YAML file. - Actionable Self-Correction Feedback: Whenever a placement or cable fails any of the 5 validation stages (26 closed
DiagnosticCodetypes), the engine returns structuredremediation_suggestionsso your AI agent fixes the collision, PoE overload, orCat5ebottleneck autonomously in the very next turn.
🖼️ Generated CAD Blueprints (100% Deterministic SVG Output)
1. Dual-Row Engineering Elevation & Z-Depth Side Cutaway (elevation.svg)
Includes Equipment Schedule, Front Elevation (X, Y), Horizontally Mirrored Rear Elevation (W_panel - X - width), Cable Callout Lanes, and Right-Hand Z-Depth Cutaway (Z_min to Z_max with Front Glass Door -50 mm and Rear Wall +300 mm clearance checks):
2. 5-Layer Logical Pin-to-Pin Wiring Schematic with VLAN & IP CIDR Badges (wiring-schematic.svg)
🚀 30-Second Quickstart
Option A: Local Node.js (>= 20) & pnpm
# 1. Clone & install
git clone https://github.com/itAlex240/rack-architect-mcp.git
cd rack-architect-mcp
pnpm install
# 2. Build all 6 packages & run the 34 test suites
pnpm build
pnpm test
# 3. Launch the Live 3D/2D Web-Viewer & Sidecar on the 8U 10-Inch Reference Homelab
pnpm start
Open http://127.0.0.1:3100/ in your browser to inspect the 3D Digital Twin, mount devices from the Catalog Drawer, route 3D spline cables, and download .SCAD / .STL / .GLB / .SVG / BOM.md deliverables!
Option B: Docker (Zero Local Dependencies)
# Run the pre-built image from GitHub Container Registry:
docker run --rm -p 3100:3100 ghcr.io/italex240/rack-architect-mcp:latest
# Or build locally:
docker build -t rack-architect-mcp .
docker run --rm -p 3100:3100 rack-architect-mcp
# Open http://127.0.0.1:3100/
Option C: CLI Validation & Headless CAD Export
# Validate any rack.yaml and print the ASCII Elevation Plan + Diagnostics
pnpm validate:demo
# Export elevation.svg, wiring-schematic.svg, BOM.md, rack-scene.glb, and all .scad + .stl 3D-print carriers
pnpm export:demo
🤖 Connect Claude Desktop, Cursor, or Antigravity
Add rack_architect_mcp to your claude_desktop_config.json, .cursor/mcp.json, or Antigravity MCP settings:
{
"mcpServers": {
"rack_architect_mcp": {
"command": "node",
"args": [
"/ABSOLUTE/PATH/TO/rack-architect-mcp/packages/cli/dist/bin.js",
"--stdio",
"--port",
"3100",
"--project",
"/ABSOLUTE/PATH/TO/rack-architect-mcp/examples/10inch-homelab/rack.yaml"
]
}
}
}
Whenever your AI agent starts the MCP server over stdio, it automatically launches the local WebSocket Sidecar at http://127.0.0.1:3100. Every tool call the AI executes (mount_equipment, connect_cables, modify_equipment, undo_redo) updates your 3D browser view in real time!
🧠 Official Open-Source Agent Skill (skills/rack-architect/SKILL.md)
This repository includes a 100% free, MIT-licensed Agent Skill (skills/rack-architect/SKILL.md & .agents/skills/rack-architect/SKILL.md) that teaches Claude Code, Cursor, GitHub Copilot, and Google Antigravity the complete 6-Phase Autonomous Rack Engineering Runbook (sub-U modular carrier pairing, -angled plug selection, all 26 diagnostic remediation patterns, and 2-manifold .STL export):
# Install the skill into Claude Code, Cursor, Copilot, or Windsurf via skills CLI:
npx skills add itAlex240/rack-architect-mcp
# Or in Google Antigravity: automatically discovered from .agents/skills/rack-architect/SKILL.md!
🖨️ Parametric 3D-Print Generator (.scad & .stl)
For every modular 3D-printed carrier (category: 'modular-carrier'), @rack-mcp/exporters automatically generates:
- Parametric OpenSCAD (
.scad): Customizable wall thickness, EIA-310 oval rack ears (9.5 × 6.5 mm), sub-U device bays (+0.35 mmtolerance for Lenovo ThinkCentre M920q, Ubiquiti UCG-Max, JetKVM), Keystone snap-in clips, side support rails, and rear PSU brick cradles with Velcro slots. - Ready-to-Slice Watertight ASCII
.stl: Computed directly in memory via 2D grid subdivision—drop straight into OrcaSlicer, Bambu Studio, or PrusaSlicer!
Pre-generated reference files in examples/10inch-homelab/:
3dprint-10inch-lenovo-tiny-plus-2keystone.scad&.stl3dprint-10inch-ucg-ultra-plus-3keystone.scad&.stl
🖥️ Live 3D Digital Twin & 2D CAD Web-Viewer (127.0.0.1:3100)
- Interactive Catalog & Cable Patch Builder (
+ Catalog & Cable Builder):- Search all 30 hardware blueprints, filter by
10inch/19inch/sub-module, selectTarget U+FRONT/REAR, and mount with 1 click. - Patch 3D Catmull-Rom cables between any two ports with optional
VLAN ID(1..4094) andIP CIDR(10.10.20.0/24) annotations.
- Search all 30 hardware blueprints, filter by
- 3D Engineering HUD:
- Camera Presets:
Perspective,Front Ortho,Rear Ortho,Left Cutaway - Toggles:
X-Ray Chassis(inspect internal mini-PCs & PSU bricks),Clearance Boxes($\Delta Z_{\text{plug}}$ wireframes),Cable Splines Explode Z (0..140 mm)slider to separate front and rear assemblies
- Camera Presets:
- W3C WebMCP Ready: Automatically registers all 11 tools on
document.modelContextwhen opened in a WebMCP-capable browser.
🛡️ 5-Stage Validation Engine (All 26 Diagnostic Codes)
| Stage | Diagnostic Codes | What Is Checked Deterministically? |
|---|---|---|
| 1. Bounds & Slots | CODE_DUPLICATE_INSTANCE_ID, CODE_UNKNOWN_BLUEPRINT, CODE_RACK_BOUNDS_EXCEEDED, CODE_SLOT_NOT_FOUND, CODE_SLOT_OCCUPIED, CODE_SLOT_BOUNDS_EXCEEDED | Rack U height, panel width (19", 10", 6"), sub-U carrier slot dimensions (mm) and allowed categories. |
| 2. 3D AABB & Doors | CODE_CHASSIS_COLLISION, CODE_CLEARANCE_COLLISION, CODE_FRONT_DOOR_VIOLATION, CODE_REAR_CLEARANCE_VIOLATION | Millimeter-exact 3D AABB overlap between front and rear equipment including dynamic plug clearances (schuko-cee7 = 55 mm, iec-c13 = 45 mm, sfp+ = 38 mm, rj45 = 35 mm). |
| 3. Power & PoE DAG | CODE_POE_BUDGET_EXCEEDED, CODE_MISSING_POWER_INPUT, CODE_EXTERNAL_PSU_UNPLUGGED, CODE_PDU_OVERLOAD | Full electrical DAG from UPS/PDU to switches, external power bricks (Lenovo 135W Slim-Tip), and PoE PSE/PD budgets (196 W). |
| 4. Cables & Speed | CODE_PORT_NOT_FOUND, CODE_PORT_ALREADY_OCCUPIED, CODE_PORT_INCOMPATIBLE, SPEED_MISMATCH, CODE_MISSING_CABLE_PORTAL, CODE_CABLE_BEND_RADIUS_VIOLATION | Connector compatibility, Cat5e bottleneck detection on $\ge 2.5\text{ GbE}$ links (SPEED_MISMATCH), front-to-rear brush portal checks, and minimum 3D spline bend radius. |
| 5. Thermal & Acoustic | THERMAL_AIRFLOW_CONFLICT, THERMAL_HOTSPOT_STACKING, CODE_THERMAL_DENSITY_HIGH, ACOUSTIC_NOISE_HIGH, CODE_WEIGHT_LIMIT_WARNING | Opposing airflow (front-to-rear vs rear-to-front), stacked high-power fanless switches, BTU/hr heat load, and logarithmic dB(A) noise addition ($L_{\text{total}} = 10 \log_{10}(\sum 10^{L_i/10})$). |
📦 Monorepo Architecture (packages/*)
| Package | Description |
|---|---|
@rack-mcp/core-domain | Pure TypeScript/Zod schemas, 3D coordinate transformer, AABB collision solver, 5-stage validator, and clamped Catmull-Rom 3D spline router (zero Node/DOM dependencies). |
@rack-mcp/hardware-catalog | 30 YAML hardware blueprints (10inch, 19inch, carriers, sub-modules), port_groups matrix expander, and catalog search/validator. |
@rack-mcp/exporters | elevation.svg, wiring-schematic.svg, BOM.md, headless binary .glb, and parametric .scad & .stl 3D-print generators. |
@rack-mcp/mcp-server | MCP server (stdio), 11 tools, 4 resources, 2 prompts, 50-step Undo/Redo manager, and local HTTP/WebSocket sidecar (:3100). |
@rack-mcp/web-viewer | React 19 + Three.js (@react-three/fiber) live 3D/2D CAD studio, Catalog/Cable Builder Drawer, and W3C WebMCP integration. |
@rack-mcp/cli | Unified rack-mcp CLI (serve, validate, export). |
🤝 Contributing & Adding Hardware Blueprints
Want to add your favorite 10-inch switch, mini-PC, or 3D-printed carrier? You can add a new YAML blueprint in under 2 minutes—see **CONTRIBUTING.md**!
📄 License
Released under the **MIT License**.
Questions fréquentes
Qu'est-ce que RackArchitect MCP ?
3D/2D Rack-as-Code homelab planner, 5-stage validator, CAD SVG/BOM & watertight STL generator.
Comment installer RackArchitect MCP ?
Suivez les étapes d'installation de sa documentation, affichée sur cette page et dans son dépôt.
Faut-il une clé API pour RackArchitect MCP ?
Son entrée au registre n'indique aucune clé ni secret obligatoire. Certaines fonctions peuvent tout de même demander un compte auprès du service auquel il se connecte.
RackArchitect MCP est-il open source ?
Oui. Son code est sur GitHub sous licence MIT.
Qui maintient RackArchitect MCP ?
Il est publié par itAlex240. AI.tn le référence sans le maintenir ni le recommander.
Issu du registre MCP officiel. Être listé n'est pas une recommandation : vérifiez le code et les permissions d'un serveur avant de lui donner accès à vos données.