io.github.chrischall/iaqualink-mcp

Registre officiel Autres

iAqualink pool equipment: status plus confirm-gated pump, heater, light and set-point control.

Installation

Ajoutez ceci à la configuration MCP de votre client (Claude Desktop : claude_desktop_config.json ; Cursor : .cursor/mcp.json ; VS Code et les autres utilisent la même forme « mcpServers »).

NPM package @chrischall/iaqualink-mcp
Claude Code
claude mcp add iaqualink-mcp -e 'IAQUALINK_EMAIL=<IAQUALINK_EMAIL>' -e 'IAQUALINK_PASSWORD=<your iaqualink_password>' -e 'IAQUALINK_STATUS_CACHE_SECONDS=<IAQUALINK_STATUS_CACHE_SECONDS>' -e 'IAQUALINK_WEBTOUCH_STREAM_HOSTS=<IAQUALINK_WEBTOUCH_STREAM_HOSTS>' -- npx -y @chrischall/iaqualink-mcp@0.2.2
Configuration JSON (Claude Desktop, Cursor, VS Code)
{
    "mcpServers": {
        "iaqualink-mcp": {
            "command": "npx",
            "args": [
                "-y",
                "@chrischall/iaqualink-mcp@0.2.2"
            ],
            "env": {
                "IAQUALINK_EMAIL": "<IAQUALINK_EMAIL>",
                "IAQUALINK_PASSWORD": "<your iaqualink_password>",
                "IAQUALINK_STATUS_CACHE_SECONDS": "<IAQUALINK_STATUS_CACHE_SECONDS>",
                "IAQUALINK_WEBTOUCH_STREAM_HOSTS": "<IAQUALINK_WEBTOUCH_STREAM_HOSTS>"
            }
        }
    }
}

Variables d'environnement

  • IAQUALINK_EMAIL The email address you sign in to the iAqualink app with (needed by every tool; the server starts without it)
  • IAQUALINK_PASSWORD secret Your iAqualink password (needed by every tool; the server starts without it)
  • IAQUALINK_STATUS_CACHE_SECONDS Seconds a system's status read is reused before re-polling iAqualink (default 5; 0 disables)
  • IAQUALINK_WEBTOUCH_STREAM_HOSTS Extra hosts (comma-separated) the WebTouch display stream may be served from, beyond webtouch.iaqualink.net and prm.iaqualink.net. Leave unset unless a WebTouch error names a new host

Documentation

Tirée du README du projet sur GitHub, actualisée chaque semaine. Les liens ouvrent GitHub.

Sommaire
  1. iaqualink-mcp
  2. Tools
  3. Setup
  4. Skills
  5. Development

MCP server for iAqualink (Zodiac / Jandy / Fluidra) pool and spa equipment. Read temperatures, set points, pumps, heaters, lights, aux circuits and salt chlorinator state, and switch equipment — every change confirmation-gated and verified by a re-read. It signs in with your own iAqualink account (the same email and password as the iAqualink app); no browser, extension or bridge.

Supports the two system types the reference client supports: iAqua (Jandy iAquaLink panels) and eXO (Zodiac salt chlorinators). Other device types on the account (robotic cleaners, …) are listed but not controlled.

Status: partly verified live. Request shapes come from iaqualink-py 0.7.0 (what Home Assistant uses) and a WebTouch capture (see docs/IAQUALINK-API.md).

  • Seen working on a real iAqua (RS) panel, 2026-10-11/12: sign-in, the system list (devices.json), the iAqua status reads (get_home, get_devices) and WebTouch (location lookup, init, button presses and the display stream).
  • Still derived, not yet exercised live: the iAqua set_* commands (pump, heater, aux, light, temperature), every eXO request (shadow read and writes), iaqualink_set_chlorinator's inferred shape, and the iQ20 schedule fallback. Every write still re-reads to confirm what happened.

This project was developed and is maintained by AI (Claude Code). Use at your own discretion.

Tools

ToolWhat it doesAnnotation
iaqualink_list_systemsSystems on the account and their serialsread
iaqualink_get_statusTemperatures, set points, pumps, heaters, aux/lights, chlorinator, salinity/pH/ORP (view: compact · full · raw)read
iaqualink_healthcheckWhether a sign-in is configured and acceptedread
iaqualink_set_equipmentPool/spa pump, pool/spa/solar heater; eXO filter pump, production, boost, low, heating — on/offwrite, not destructive
iaqualink_set_auxAux circuit or light on/off (by number, aux_<n> or label)write, not destructive
iaqualink_set_lightDimmable brightness (0/25/50/75/100) or color effect (iAqua)write, not destructive
iaqualink_set_temperaturePool and/or spa set point (iAqua °F/°C; eXO °C pool)write, not destructive
iaqualink_set_chlorinatoreXO chlorinator output % — inferred shape, not in iaqualink-pywrite, not destructive
iaqualink_list_schedulesRS panel programs via WebTouch (iAqua; iQ20 fallback probe); eXO timersread
iaqualink_add_scheduleAdd an RS panel program (circuit, start, stop, run days) via WebTouchwrite, not destructive
iaqualink_edit_scheduleChange an RS panel program's start / stop / run days via WebTouchwrite, not destructive
iaqualink_delete_scheduleDelete an RS panel program via WebTouch — no undowrite, destructive
iaqualink_set_scheduleSet / re-time / disable an eXO timer (start–stop, rpm on variable-speed pumps) — eXO only, unverified livewrite, not destructive
iaqualink_check_panelIs an RS system online, and what is its panel showing (screen, open dialog, Edit mode with unsaved changes)? Run it when the app and these tools disagreeread
iaqualink_list_pump_speedsRS panel variable-speed pump: the named speeds, their RPM and which one runs, via WebTouchread
iaqualink_set_pump_speedRun the pump at a named speed via WebTouchwrite, not destructive
iaqualink_set_pump_speed_rpmChange a named speed's RPM (600–3450) via WebTouch; a speed that is not running runs briefly while set, then the running speed is restoredwrite, not destructive
iaqualink_list_onetouchRS panel OneTouch scenes (Spa Mode, All OFF, …) and their state, via WebTouchread
iaqualink_set_onetouchTurn a OneTouch scene on/off via WebTouch — toggle not exercised live yetwrite, not destructive

Every write has an inverse in this set and reaches no other person — except deleting a panel program, which the panel stores immediately with no undo, so that one is marked destructive.

Schedules and OneTouch on a Jandy AquaLink RS panel go through WebTouch, the panel emulation the iAqualink web app uses: the server opens the panel's display stream, presses the same buttons a person would (checking before every press that the panel is on the expected screen and row, and aborting otherwise), returns to Home, and re-reads to verify. Only one WebTouch session per system runs at a time. The add / edit / delete sequences follow a live capture on an RS panel (2026-10-11) — see docs/IAQUALINK-API.md. If WebTouch is unavailable, iaqualink_list_schedules falls back to iQ20 schedules (adapter firmware 3+), probing r-api.iaqualink.net/v2 (Bearer), p-api.iaqualink.net/v2 (Bearer), p-api.iaqualink.net/v2 (bare token) and prm.iaqualink.net/v1 (bare token) once each and reporting every attempt. iQ20 schedule writes are not built.

How a write works. It reads the current state first and sends nothing if it already matches — iAqua's pump/heater/aux commands are toggles, so a blind send would flip whatever the state happened to be. It then asks you to confirm (an elicitation prompt where the client supports one; otherwise a preview plus a confirmToken, bound to the state it was planned against), sends, and re-reads until the requested value shows up. The result is confirmed, unchanged, or sent-unconfirmed with what was observed (eXO applies changes asynchronously — check again rather than retrying).

Setup

npm i -g @chrischall/iaqualink-mcp
VariableRequiredMeaning
IAQUALINK_EMAILfor every toolYour iAqualink app sign-in email
IAQUALINK_PASSWORDfor every toolYour iAqualink password (not trimmed)
IAQUALINK_STATUS_CACHE_SECONDSnoSeconds a status read is reused (default 5; 0 disables)
IAQUALINK_WEBTOUCH_STREAM_HOSTSnoExtra hosts (comma-separated) the WebTouch display stream may come from; default only prm.iaqualink.net
MCP_CONFIRM_MODEnoask-user (default) / auto / refuse
MCP_CONFIRM_TTL_SECONDSnoconfirmToken lifetime (default 600)
MCP_CONFIRM_ELICITATIONnooff skips the prompt even on clients that declare elicitation

The server starts without credentials (so hosts can list its tools) and reports them missing on the first call. A rejected password is never retried: the refusal is remembered until the server restarts, so a typo cannot lock the account.

Claude Code: claude mcp add iaqualink -e IAQUALINK_EMAIL=… -e IAQUALINK_PASSWORD=… -- npx -y @chrischall/iaqualink-mcp

Hosted (claude.ai)

mint.yaml declares per-user children with an email/password form on the connector's authorize page (each person signs in as themselves), egress to exactly prod.zodiac-io.com, r-api.iaqualink.net, p-api.iaqualink.net (iQ20 probe only) and prm.iaqualink.net (WebTouch, and the iQ20 probe); the WebTouch display stream is refused on any other host unless it is added to IAQUALINK_WEBTOUCH_STREAM_HOSTS (and egress). No persistent state — the session lives in memory and one sign-in rebuilds it after a cold start.

Skills

  • skills/iaqualink — how to use these tools.
  • skills/iaqualink-curl — the same reads straight from a shell with curl, credentials from the macOS Keychain (the sign-in, system list and iAqua reads are seen live; the eXO shadow read is still derived from iaqualink-py).

Development

npm install
npm run build
npm run test:coverage   # typecheck (src + tests) + vitest, 100% coverage — what CI runs

Tests run the real client against an in-memory iAqualink (tests/support/fake-server.ts) built from iaqualink-py's fixtures.

Questions fréquentes

Qu'est-ce que io.github.chrischall/iaqualink-mcp ?

iAqualink pool equipment: status plus confirm-gated pump, heater, light and set-point control.

Comment installer io.github.chrischall/iaqualink-mcp ?

Il s'exécute sur votre machine. Dans Claude Code : claude mcp add iaqualink-mcp -e 'IAQUALINK_EMAIL=<IAQUALINK_EMAIL>' -e 'IAQUALINK_PASSWORD=<your iaqualink_password>' -e 'IAQUALINK_STATUS_CACHE_SECONDS=<IAQUALINK_STATUS_CACHE_SECONDS>' -e 'IAQUALINK_WEBTOUCH_STREAM_HOSTS=<IAQUALINK_WEBTOUCH_STREAM_HOSTS>' -- npx -y @chrischall/iaqualink-mcp@0.2.2. Pour les autres clients, collez la configuration JSON de cette page dans leurs réglages MCP.

Faut-il une clé API pour io.github.chrischall/iaqualink-mcp ?

Oui. Il attend IAQUALINK_PASSWORD, à renseigner dans sa configuration.

io.github.chrischall/iaqualink-mcp est-il open source ?

Oui. Son code est sur GitHub sous licence MIT.

Qui maintient io.github.chrischall/iaqualink-mcp ?

Il est publié par chrischall. AI.tn le référence sans le maintenir ni le recommander.

Issu du registre MCP officiel. Être listé n'est pas une recommandation : vérifiez le code et les permissions d'un serveur avant de lui donner accès à vos données.