Deterministic AI data-center design for Korea (NVIDIA Rubin era, 22.9 kV intake): rack count, PUE, total MVA, cooling split, CDU planning, cost and timeline.
Installation
Les étapes d'installation sont dans la documentation ci-dessous. Documentation
Documentation
Tirée du README du projet sur GitHub, actualisée chaque semaine. Les liens ouvrent GitHub.
Sommaire
AIDC-AI.IO — MCP Connector
AI data center sizing, validation, and layout via a remote MCP server.
AI 데이터센터 자동화 툴: 결정론적 엔진으로 AI 데이터센터를 설계·검증·레이아웃합니다.
What is this?
This repository shows how to connect an MCP client or REST client to the AIDC-AI.IO Design Engine — a deterministic, source-backed engine that sizes, validates, and lays out Rubin-era AI data centers.
What the engine does (on the server):
- Accepts an IT load, rack density, GPU generation (Hopper / Blackwell / NVIDIA Vera Rubin NVL72 / VR200), and site constraints.
- Returns deployment-unit-snapped rack counts, design PUE, power-factor-backed total MVA (22.9 kV intake), liquid-cooling / air-cooling heat split, CDU planning values, cost (KRW), and timeline.
- Validates designs against electrical, cooling, layout, safety, and data rules with severity-classified findings and RFIs.
- Generates a rack-plan grid (hall dimensions, row/column positions in mm) and a site-block layout.
What this repo contains:
- MCP client configuration snippet.
curland Node.js examples that call the public REST projection (/api/agent/*).- Authenticated runnable examples that read the current response shape.
The core calculation engine, reference catalogs (rack library, AHJ/code matrix, 1.6T fabric topology, direct-to-chip (D2C) cooling models, etc.) are proprietary and remain server-side. No engine source is published here.
Korea live. Region-specific: 22.9 kV utility intake, Korean AHJ/code, climate, and operations validation. Keywords the engine targets: AI data center, AIDC, NVIDIA Rubin, Vera Rubin, 22.9kV, liquid cooling, CDU, D2C, 1.6T fabric, PUE.
MCP Server
| Field | Value |
|---|---|
| Transport | Streamable HTTP |
| Endpoint | https://aidc-ai.io/api/mcp |
| Official registry name | io.aidc-ai/design-engine |
| Registry descriptor | remote.server.json (metadata revision 1.0.1; separate from npm/API versions) |
| Auth | Registered API key required. Configure Authorization: Bearer in the client credential settings; never send keys in tool arguments. |
| Tool count | 3 |
| Limits | The registered account limits apply; preserve HTTP 429 and Retry-After. |
Tools
| Tool | One-line description |
|---|---|
design | Size an AI data center: returns rack count, PUE, total MVA, liquid/air cooling split, CDU count, cost (KRW), and build timeline. |
validate | Check a design against electrical, cooling, layout, safety, and data rules; returns severity-classified findings and RFIs. |
layout | Generate a rack-plan grid (hall dimensions, row/column positions in mm) and a site-block layout. |
Quick Start
MCP client configuration
Obtain a registered integration key through AIDC Contact.
Use a client that supports Streamable HTTP and pass the key through its
credential settings as an Authorization: Bearer header. The mcp.json
example contains a replacement marker, not a working credential. Keep the
configured copy private and never commit a real key.
For a local stdio client, the published package is available through npm:
npx -y aidc-mcp-server@0.2.4
Set AIDC_API_KEY in the MCP server process's environment using your client's
secret or environment configuration. A file next to the server is not read
automatically. design, validate, and layout do not accept credentials
as tool inputs. Authentication errors are connection-configuration failures,
not engineering verdicts.
Docker (local stdio server)
Build and run the same published MCP server used for registry evaluation:
docker build -t aidc-ai-mcp .
docker run --rm -i -e AIDC_API_KEY aidc-ai-mcp
The container communicates over stdio and connects to https://aidc-ai.io by
default. Export a registered AIDC_API_KEY before running the container;
-e AIDC_API_KEY forwards the existing variable without placing its value in
the command text.
REST Usage
The MCP package calls these REST endpoints. All calculation routes require a registered key:
| Tool | REST endpoint |
|---|---|
design | POST https://aidc-ai.io/api/agent/design |
validate | POST https://aidc-ai.io/api/agent/validate |
layout | POST https://aidc-ai.io/api/agent/layout |
Example: size a 30 MW Rubin-era AI data center
curl -s -X POST https://aidc-ai.io/api/agent/design \
-H "Content-Type: application/json" \
-H "Authorization: Bearer ${AIDC_API_KEY}" \
-d '{
"itLoadMw": 30,
"rackDensityKw": 120,
"gpuGen": "rubin",
"siteAreaSqm": 5000,
"region": "metropolitan",
"options": {
"redundancy": "n_plus_1",
"coolingMode": "liquid",
"pueTarget": 1.2
}
}'
Read the response
Use node design.example.js for a live authenticated example. Successful
responses contain ok, summary, warnings, engineVersion, requestId,
and _agent. Sizing values such as rackCount, pueDesign, and mvaTotal
are inside summary. Preserve warnings and validation findings; an ok: true
response does not certify the design or turn PENDING into PASS.
There is no fixed numeric output fixture for a real project. Use the returned engine result and its evidence for the exact selected inputs.
Tools — Input Reference
design
Size an AI data center from scratch.
| Field | Type | Range / values | Required | ||
|---|---|---|---|---|---|
itLoadMw | number | 0 < x ≤ 1000 | Yes | ||
rackDensityKw | number | 0 < x ≤ 500 | Yes | ||
gpuGen | string | "hopper" \ | "blackwell" \ | "rubin" | Yes |
siteAreaSqm | number | 0 < x ≤ 1 000 000 | Yes | ||
region | string | "metropolitan" \ | "regional" | Yes | |
options.redundancy | string | "n" \ | "n_plus_1" \ | "2n" | No |
options.coolingMode | string | "air" \ | "hybrid" \ | "liquid" | No |
options.pueTarget | number | 1.0 – 2.5 | No |
Key response fields: summary.rackCount, optional summary.unsnappedRackCount,
summary.pueDesign, summary.mvaTotal, and cooling/commercial values inside
summary. warnings[], engineVersion, and requestId are top-level fields.
validate
Check a design against engineering rules.
{
"rawInput": {
"itLoadMw": 30,
"rackDensityKw": 120,
"gpuGen": "rubin",
"siteAreaSqm": 5000,
"region": "metropolitan"
}
}
Key response fields: findings[] (including severity, family, message,
and optional publicRuleId), rfis[], and optional verdict / graphVerdict.
Public MCP accepts rawInput or designSummary; private EngineSession IDs
remain in the signed-in AIDC workflow.
layout
Generate a rack plan and site block layout.
{
"design": {
"itLoadMw": 30,
"rackDensityKw": 120,
"gpuGen": "rubin",
"siteAreaSqm": 5000,
"region": "metropolitan"
},
"siteCentroid": { "lat": 37.5665, "lng": 126.9780 },
"siteAreaSqm": 5000
}
Key response fields: rackPlan (hall dimensions, rows, columns, per-rack positions in mm),
sitePlan (block-level layout in percentage coords)
Links
| Resource | URL |
|---|---|
| Website | https://aidc-ai.io |
| OpenAPI 3.1 spec | https://aidc-ai.io/api/openapi.json |
| MCP server card | https://aidc-ai.io/.well-known/mcp/server.json |
| LLM context | https://aidc-ai.io/llms.txt |
| Full LLM context | https://aidc-ai.io/llms-full.txt |
| Contact | contact@aidc-ai.io |
License
This repository (examples and connector code only) is released under the MIT License.
The AIDC-AI.IO engine, reference catalogs, and all server-side logic remain proprietary.
Questions fréquentes
Qu'est-ce que Aidc AI MCP ?
Deterministic AI data-center design for Korea (NVIDIA Rubin era, 22.9 kV intake): rack count, PUE, total MVA, cooling split, CDU planning, cost and timeline.
Comment installer Aidc AI MCP ?
Suivez les étapes d'installation de sa documentation, affichée sur cette page et dans son dépôt.
Aidc AI MCP est-il open source ?
Oui. Son code est sur GitHub sous licence MIT.
Qui maintient Aidc AI MCP ?
Il est publié par aidc2026ai-melon. AI.tn le référence sans le maintenir ni le recommander.
Issu des listes communautaires awesome-mcp-servers et du dépôt GitHub du projet. Être listé n'est pas une recommandation : vérifiez le code et les permissions d'un serveur avant de lui donner accès à vos données.