Siglent SDM3045X multimeter
Measurements with a Siglent SDM3045X bench multimeter via USB or LAN (unofficial)
Install
Add this to your client's MCP configuration (Claude Desktop: claude_desktop_config.json; Cursor: .cursor/mcp.json; VS Code and others use the same "mcpServers" shape).
mcp-server-siglent-sdm3045xclaude mcp add siglent-sdm3045x-multimeter -e 'SDM_RESOURCE=<SDM_RESOURCE>' -e 'SDM_SERIAL=<SDM_SERIAL>' -e 'SDM_ALLOW_SCPI=0' -e 'SDM_VISA_BACKEND=@py' -- uvx mcp-server-siglent-sdm3045x==0.1.0
{
"mcpServers": {
"siglent-sdm3045x-multimeter": {
"command": "uvx",
"args": [
"mcp-server-siglent-sdm3045x==0.1.0"
],
"env": {
"SDM_RESOURCE": "<SDM_RESOURCE>",
"SDM_SERIAL": "<SDM_SERIAL>",
"SDM_ALLOW_SCPI": "0",
"SDM_VISA_BACKEND": "@py"
}
}
}
}
Environment variables
SDM_RESOURCEInstrument address: /dev/usbtmc0, an IP address or a VISA resource string. Auto-detected on USB and in the local network if not set.SDM_SERIALSerial number of the instrument to use when several are connected (auto-detection only)SDM_ALLOW_SCPISet to 1 to enable the raw SCPI tool, which can change any instrument settingSDM_VISA_BACKENDPyVISA backend: @py (pyvisa-py) or @ivi for an installed NI/Keysight VISA
Documentation
From the project's README on GitHub, refreshed weekly. Links open on GitHub.
Contents
mcp-server-siglent-sdm3045x
An MCP server that lets AI assistants take measurements with a Siglent SDM3045X bench multimeter connected via USB or LAN.
Unofficial project, not affiliated with or endorsed by Siglent. Tested with an SDM3045X, firmware 5.02.01.10, over USB (Linux) and LAN.
Tools
| Tool | Description |
|---|---|
read | One reading with the function and range set on the instrument, without changing them |
measure | Select a function (DC/AC voltage and current, 2/4-wire resistance, capacitance, frequency, period, continuity, diode, temperature) and take one reading |
sample | Timestamped readings over a period (max 600 s, interval ≥ 0.1 s) with min/max/mean/stdev |
burst | Up to 10000 readings as fast as the instrument can (about 180/s at speed fast), with statistics |
get_device_info | Model, serial number, firmware, connection and the present measurement configuration |
Every reading comes with its unit, the range used and, where the data sheet gives a single
figure, its accuracy (e.g. ±(0.06 % of reading + 8 counts) as an absolute value). Overloads
are reported as "overload": true instead of the instrument's 9.9E37.
With --allow-scpi one more tool is available:
| Tool | Description |
|---|---|
scpi | Send any SCPI command or query from the Remote Manual (statistics, limits, null, …) |
The raw SCPI tool is off by default because it can change any setting, including the LAN configuration.
Requirements
- Python ≥ 3.10 and uv
- The instrument connected to the USB device port on the rear, or to the network.
- Linux, USB: the kernel
usbtmcdriver makes the instrument available as/dev/usbtmc0. Give logged-in users access with a udev rule:echo 'SUBSYSTEM=="usbmisc", KERNEL=="usbtmc[0-9]*", TAG+="uaccess"' | sudo tee /etc/udev/rules.d/70-usbtmc.rules sudo udevadm control --reload && sudo udevadm trigger - Windows / macOS, USB: install a VISA (NI-VISA or Keysight IO Libraries) and start the
server with
--visa-backend @ivi. - LAN: no extra software. The instrument needs an address in your subnet; then the server
finds it by itself. On the instrument open Utility → I/O Config → LAN Settings and turn on
DHCP, or enter a static IP address, subnet mask and gateway under Modify Settings (User
Manual, section I/O Configuration, available on the
Siglent product page). Check that the
instrument's subnet matches your network: ours came with the static address 10.11.13.220,
which the broadcast search does not reach. While USB is connected,
SYST:COMM:LAN:IPAD?(e.g. with thescpitool) shows the address in use.
Configuration
Claude Code
claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x
# fixed address instead of auto-detection:
claude mcp add siglent-sdm3045x -- uvx mcp-server-siglent-sdm3045x --resource 192.168.1.50
Claude Desktop and other clients
{
"mcpServers": {
"siglent-sdm3045x": {
"command": "uvx",
"args": ["mcp-server-siglent-sdm3045x"]
}
}
}
Options
| Option | Environment variable | Default |
|---|---|---|
--resource RESOURCE | SDM_RESOURCE | auto-detect on USB, then LAN |
--serial SERIAL | SDM_SERIAL | any SDM3045X |
--allow-scpi | SDM_ALLOW_SCPI=1 | off |
--visa-backend BACKEND | SDM_VISA_BACKEND | @py (pyvisa-py) |
--log-level LEVEL | SDM_LOG_LEVEL | WARNING |
RESOURCE can be a device file (/dev/usbtmc0), an IP address or host name (VXI-11), or any
VISA resource string such as TCPIP::192.168.1.50::5025::SOCKET (raw socket) or
USB0::0xF4EC::0x1203::SDM34XXXXXXXXX::INSTR. Port 5024 is a telnet console and does not work
as a socket resource.
Auto-detection tries /dev/usbtmc* first, then Siglent instruments listed by VISA on USB, then
VXI-11 instruments in the local network (UDP broadcast to the portmapper, about 1 s). It accepts
the first one that identifies itself as an SDM3045X. With several instruments, --serial picks
one by its serial number (shown by get_device_info, on the rear label and under
Utility → System Setup → System Info). Set --resource instead if the instrument is in
another subnet, where the broadcast does not reach it; the two options exclude each other.
Measurement notes
- The server cannot see how the test leads are connected. It tells the assistant to only switch to functions that match the wiring: currents need the red lead in the I jack; resistance, continuity, diode and capacitance drive a test current of up to 1 mA through the circuit.
- Switching function or range remotely also changes what the front panel shows.
- Once the server has sent a command, the instrument is in remote mode: the front panel shows "Immediate Trig" and its keys are locked. Press Shift to return to front panel operation. The instrument offers no remote command for this, so the server cannot release it by itself.
- Above 7 A, the data sheet recommends 30 s off after 30 s on.
- Accuracy figures are the one-year data sheet values (23 °C ± 5 °C, 30 min warm-up, speed slow). 2-wire resistance adds 0.2 Ω unless the leads were nulled; AC accuracy depends on the signal frequency and is given per frequency band; thermocouple figures exclude the cold junction error (up to ±3.5 °C with the built-in sensor).
Development
uv sync
uv run pytest # tests use a simulated instrument
npx @modelcontextprotocol/inspector uv run mcp-server-siglent-sdm3045x # try the tools interactively
To check a real instrument, connect it and run:
uv run python scripts/hardware_test.py # voltage-type functions only
uv run python scripts/hardware_test.py --with-test-current # also resistance, current, capacitance, …
uv run python scripts/hardware_test.py --reconnect # also unplug/replug USB when asked
The basic checks only use functions that put no current into the inputs. Observed instrument behaviour, including where it differs from the Remote Manual, is described in docs/protocol.md.
License
MIT
Frequently asked questions
What is Siglent SDM3045X multimeter?
Measurements with a Siglent SDM3045X bench multimeter via USB or LAN (unofficial)
How do I install Siglent SDM3045X multimeter?
It runs on your machine. In Claude Code: claude mcp add siglent-sdm3045x-multimeter -e 'SDM_RESOURCE=<SDM_RESOURCE>' -e 'SDM_SERIAL=<SDM_SERIAL>' -e 'SDM_ALLOW_SCPI=0' -e 'SDM_VISA_BACKEND=@py' -- uvx mcp-server-siglent-sdm3045x==0.1.0. For other clients, paste the JSON configuration from this page into their MCP settings.
Does Siglent SDM3045X multimeter need an API key?
Its registry entry lists no required key or secret. Some features may still need an account with the service it connects to.
Is Siglent SDM3045X multimeter open source?
Yes. Its code is on GitHub under the MIT license.
Who maintains Siglent SDM3045X multimeter?
It is published by shaag7967. AI.tn lists it but does not maintain or endorse it.